SAFR-C-21 · ten indicators on the 4-point scale · target ≥ 3.60 · reviewed monthly

Core — buildable now
Org effectiveness score
3.42
▼ below 3.60 target
Personnel tracked
1,284
across 3 sites
Assessments this month
417
▲ 92% coverage
Safety-gate trips
6
require action

Ten organizational indicators

Aurora Data Campus · April

12-month trend

target 3.6
Climbing toward target — 3.42 now, +0.31 over the year.

Score distribution

Watching for grade compression — too many 3s starves the 3.6 target.
1 · 4%
2 · 14%
3 · 58%
4 · 24%
▸
Drill down anywhere. Use the breadcrumb at the top — Campus → Building → Zone → Individual — to see this same scorecard at every level. Try clicking an individual.

Procedure Library

The SAFR publication, digitized · 4 series (Core / Admin / Electrical / Mechanical), ≈65 procedures · every document validated against the SAFR standard

Core — buildable now
DocumentTitleRevStatusQuality self-score
SAFR-C-10 Feedback, Coaching & Observations02 Needs remediation 2.4
SAFR-C-21 Organizational Effectiveness02 Needs remediation 2.7
SAFR-C-17 Equipment Sealing02 Needs remediation 2.3
SAFR-C-4Human Performance 02Clean3.4
SAFR-C-15Torque Practices 02Entity mismatch2.9
SAFR-M-3Vibration Data Collection (measured) 02?Rev mismatch2.6
SAFR-M-4Fuel-Oil Analysis (measured) draftUnreleased draft1.9
…and ≈57 more across the C / A / E / M series (≈65 total) — awaiting upload. E/M procedures carry machine-checkable acceptance criteria (ISO codes, ppm, torque values).
SAFR-A-1Performance Tracking & Trending —Awaiting upload—
SAFR-A-15Action Item Process —Awaiting upload—
▸
Click SAFR-C-10, SAFR-C-17 or SAFR-C-21 to see the platform flag the real defects in your own source documents. The system holds your standards to your standard.

FCO Assessment

Live observation card · subject: T. Okafor (Technician) · Zone 3, Building A

Core — buildable now

Observation & Coaching

1 Unsat · 2 Needs Improvement · 3 Satisfactory · 4 Excellent

Overall card score

3.63
Excellent range

Weighted mean · Compliance & Safety weighted ×2.
▸
Try this: set Safety Practices to 1. Watch the overall score — strong marks everywhere else will not rescue a safety failure. That's the Safety Gate.

My Training

Electrical Commissioning Technician · Qualification path

Core — buildable now
Path progress
62%
8 of 13 modules
Next deadline
May 14
Module 9 quiz
Certifications
3
1 renews in 40d
Avg exam score
88%
▲ above pass

Learning path

linked to SAFR procedures
✓
Human Performance Fundamentals — Core 4
Reading + quiz·4
✓
Error Precursors & STAR self-checking
Animation·3
9
Switchboard Energization — start-up procedure
Video + practice·in progressquiz due May 14
10
Concurrent Verification & meter wiring
Video·locked until M9
11
Integrated Systems Test (IST) overview
Reading

Current lesson

▶
Video · Switchboard energization (4:12)

Reminders

● Module 9 quiz due in 4 days
● Arc-flash cert renewal — 40 days
● Monthly safety briefing — Fri 7:00a

Facility Map & Wayfinding

Blueprint-aware location · geofenced safety · documents that apply where you stand

Vision — roadmap (needs site hardware)

Building A · Level 2

You are in: Zone 3 — MV Switchgear
Zone 1 · Controls Zone 2 · Battery (restricted) Zone 4 · MDA Zone 5 · Mechanical Zone 3 · MV Switchgear
⚠ Live safety alert
Energized MV equipment in Zone 3. Arc-flash PPE Category 2 required. Concurrent Verification in effect.
Positioning shown is illustrative. Real deployments tier this: QR/RFID (zone-level), BLE beacons (~1–3 m), UWB (cm-class) where hardware is installed. 3D view is a later phase.

Applies to Zone 3 right now

Auto-pulled by location
SAFR-C-10 Concurrent Verification standard
SAFR-A-1 Energized-equipment logging
⚑ Arc-flash PPE Cat. 2 · LOTO protocol
▶ Switchgear walkdown (video, 6:40)

Find your way

▸
Walking directions to Zone 4 · MDA — 2 min, 48 m. Avoids restricted Zone 2.

Document Onboarding

Load your corpus · the AI helper validates each asset and proposes improvements

Core — buildable now
Drag-and-drop accepted · auto-classified by type

Import pipeline

AI proposes · a human approves · nothing auto-publishes

Uploaded 2

SAFR-A-1
Tracking & Trending
SAFR-A-15
Action Items

Parsing 1

Blueprints
Building A · 4 floors

Needs review 2

SAFR-C-10
FCO
⚠ 5 issues flagged
SAFR-C-21
Org Effectiveness
⚠ 6 issues flagged

Owner sign-off 6

Category weights
Safety-gate policy
+4 scoring decisions

Published 3

Glossary
41 terms extracted
Roles
PD · Super · Tech
Videos
12 → CDN
▸
The same approval queue handles document fixes, AI content updates, and improvement suggestions — one governance pattern. Safety and procedure changes route to the document owner specifically.

Asset Registry

The E-package goes in → the asset list comes out. Everything else hangs off it: LOTO, seals, test scope, turnover.

Core — buildable now
▸
“The asset list is everything.” Sometimes the client hands you one — “but I have never seen an accurate one.” So we build it from the drawings, flag what we can’t verify, and carry it forward to the next building asking only what changed.

E-package intake

Building A · Rev 65%
Drawings for data centers always lag — we work from 65% and reconcile.

Extracted assets

awaiting extraction
—assets
—seals to track
—LOTO points
—need verification

One asset → four downstream consumers

the same record, read by every Dhabi company
SWGR-068-BSwitchgear · Zone 3
→
LOTO6 isolation points, 2 sources
Sealing10 tamper-proof seals
Test scope14 ITRs · megger, torque, P2P
Turnoverevidence package · system B
Every penetration a door could open gets a tamper-proof seal, and the seal count is a property of the asset — so the sealing procedure, the LOTO, and the test scope all derive from one accurate list.

The LOTO Table

Electrical room, at the equipment: the drawing, the manuals, the logs and the test — on one screen instead of a folding table

Core — buildable now
▸
Scan the tag or let GPS place you, and the device already knows which asset you’re standing at, which procedure applies, and whether you’re qualified to do it.
SWGR-068-B · One-line
Sheet E-204 · Rev 65% · Zone 3
◎ located by QR
Power Control Grounding Labels
UTIL 13.8kV 52-M1 XFMR-6 · 13.8kV/480V BUS B · 480V 4000A
Tap two test points to set up a point-to-point check

Point-to-point

select 2 points

At hand

no folding table required
▤SAFR-C-15 Torqueopens at your step
▦Switchgear IB214 pp · searchable
◷Test historylast megger 412 MΩ
⚿Active LOTO#2026-0418 · verified

Inspection & Test Record

Field measurement → live pass/fail vs the SAFR acceptance criteria → qualification-gated e-sign → turnover

Core — buildable now
E-2 Insulation Resistance (Megger)
1000 VDC
Asset SWGR-068-B · Busway Run B-12 · Zone 3 · Acceptance ≥ 100 MΩ
Measured value60 MΩ
Drag the reading — pass/fail checks live against spec.
Turnover — Busway System B
ITRs roll up to system completion + owner turnover, with punch items and hold points. A FAIL raises a punch and blocks turnover.

Digital Twin — DG-3

Point-and-know AR: layout, sequence-of-events, live instruments, guided repair, and a voice agent — built by SAFR (source-agnostic)

Vision — roadmap
● LIVE · as-built 3D twin
⎍ SAFR digital twin · optional CAD import
LayoutOperateInstrumentsRepair
▶
Instructional clip · DG-3 start-up · 0:42
Ask the twin
AI · voice
Ask about DG-3 — start sequence, specs, or a fault. I'll answer and speak back.
Start sequenceSpecsFix a fault

Continuous Improvement

2 Second Lean engine · the platform studies how it's used and proposes waste reductions

Core — buildable now

AI-proposed improvements

awaiting human approval
▸
The hard line: the AI never edits safety or procedure content on its own. It proposes; a person decides. Every decision is logged. Self-modifying production systems are not how a safety platform should work.